The "V6" upgrade guide (v5.0.1 to v6.0.0-2) :
For a full overview of the latest upgrades, please refer to "Notes on network upgrades".
Step 0 - Don't panic
At the point of proposed upgrade, user will see the error message on the chain-maind similar to the below:
ERR UPGRADE "v6.0.0-2" NEEDED at time: xxxxxxxxxxxxx: {"binaries":{"darwin/amd64":.......
Don't panic - The Chain will be paused to allow the majority of validators to upgrade. Validators and full node hosts will have to upgrade your Cronos POS Chain nodes to the latest release binary.
Backups
Before the upgrade, validators are encouraged to take a complete data snapshot. Snapshotting depends heavily on infrastructure, but generally, we can do this by backing up the .chain-maind directory.
It is critically important for validator operators to back-up the .chain-maind/data/priv_validator_state.json file after stopping the chain-maind process. This file is updated every block as your validator participates in consensus rounds. It is a critical file needed to prevent double-signing if the upgrade fails and the previous chain needs to be restarted.
Step 1 - Get the v6.0.0-2 binary
To simplify the following step, we will be using Linux for illustration. Binary for Mac(arm64) and Windows are also available.
Terminate the
chain-maind; afterward, download thev6.0.0-2released binaries from GitHub:$ curl -LOJ https://github.com/crypto-org-chain/chain-main/releases/download/v6.0.0-2/chain-main_6.0.0-2-testnet_Linux_x86_64.tar.gz $ tar -zxvf chain-main_6.0.0-2_Linux_x86_64.tar.gz
Step 1.1 - Verify the version
You can verify the installation by checking the version of chain-maind, the latest version is 6.0.0-2.
Step 1.2 - Insert new configuration
Several new fields under ~/.chain-maind/config/app.toml have been introduced, kindly add the following fields to the app.toml:
Under
Base Configuration, please align theapp-db-backendwith thedb-backendfield under~/.chain-maind/config/config.toml, for example, if it isgoleveldb(default), then we can add:
Under
Rosetta Configuration:Under
gRPC Configuration:
Step 2. - Run everything
We are ready to start the node join the network again with the new binary:
Start
chain-maind, e.g.:
Afterwards, sit back and wait for the syncing process. You can query the node syncing status by
If the above command returns false, it means that your node is synced; otherwise, it returns true and implies your node is still catching up.
At this step, you've successfully performed the new binary upgrade!